AC1 Electrical Services Logo

Smoke, Heat and Carbon Monoxide Alarm Installation Across the South East of England

NICEIC Approved Contractor
NICEIC Domestic Installer
Constructionline Gold
SafeContractor
SSIP accreditation
Common Assessment Standard certification through Constructionline Gold
Registered Competent Person Electrical / Competent Person Scheme
Electrotechnical Certification Scheme (ECS)

Mains-Powered Alarm Systems for Safer Properties

A correctly selected and interconnected alarm system provides early warning throughout the property. We install new mains-powered systems, replace expired or faulty alarms, upgrade existing detection and alter alarm arrangements where the property layout or use has changed.

The appropriate combination can include optical smoke alarms, heat alarms, multi-sensor fire alarms, carbon monoxide alarms and compatible control or interconnection equipment. The final design depends on the rooms, escape routes, occupancy, existing wiring, property use and required level of protection.

Smoke detector being installed in a property in Hertford
Early warning, properly installed

Choosing the Right Type of Alarm

Optical Smoke Alarms

Detect visible smoke particles associated with slow, smouldering fires. They are commonly used in bedrooms, hallways, landings and appropriate living areas, but should not normally be positioned where steam or cooking fumes could cause unwanted alarms.

Heat Alarms

Respond to temperature rather than smoke. They are commonly used in kitchens and garages where cooking fumes, steam or dust could cause a smoke alarm to activate unnecessarily. A heat alarm should form part of an appropriate system rather than being relied upon as the property's only fire detection.

Multi-Sensor Fire Alarms

Combine optical smoke and heat sensing. The sensors work together to detect different fire characteristics while helping to reduce unwanted alarms. They can be suitable for living rooms, bedrooms, hallways, landings and other appropriate areas.

Carbon Monoxide Alarms

Detect carbon monoxide associated with fuel-burning appliances and other combustion risks. Carbon monoxide cannot be seen, smelled or tasted. A CO alarm supplements the fire-alarm system and does not replace smoke or heat detection. An activation must never be ignored; occupants should move into fresh air and follow the alarm manufacturer's emergency instructions.

Combined Heat and Carbon Monoxide Alarms

Provide heat and CO detection within one compatible unit. They may suit a kitchen or garage containing an applicable combustion risk, subject to the property assessment and correct positioning.

Mains-Powered and Battery-Powered Options

Our principal offering is mains-powered detection with backup batteries. We can also supply and fit suitable Aico sealed-battery alarms where a battery-powered system is appropriate. Battery-powered alarms are charged as the selected product plus the applicable fitting cost and must still meet the required system grade, coverage category and property requirements.

Control, Accessibility and Interconnection Equipment

Compatible test, locate and silence controls, wireless modules, alarm interfaces, strobes and vibrating pads can be considered where required.

Room-by-Room Alarm Guide and Our Aico Options

This is general guidance only. The final alarm type and position must reflect the property, room use, manufacturer's instructions, applicable standards and any fire-risk or licensing requirements.

AC1 engineers on site in hi-vis reviewing inspection notes

Which Alarm Should Be Installed in Each Room?

General room guide:

  • Kitchen — Heat alarm

  • Bedroom — Optical smoke or multi-sensor fire alarm

  • Hallway or landing — Optical smoke or multi-sensor fire alarm

  • Living or dining room — Multi-sensor fire alarm

  • Garage — Heat alarm or an alarm selected for the environment

  • Loft or utility area — Appropriate alarm selected following assessment

  • Near a boiler, fireplace or relevant fuel-burning appliance — Carbon monoxide alarm positioned in accordance with the manufacturer's guidance

  • Bathroom or shower room — An alarm is not normally positioned where steam or condensation could interfere with operation

AC1 office team member who acts as your dedicated point of contact

Aico Alarm Options

We offer a choice of Aico mains-powered and suitable battery-powered alarms. The correct range depends on the property, required system grade, room, existing installation, interconnection requirements and customer preference.

Aico Ei140e Series — Mains-Powered Standard / Grade D2

Mains-powered optical smoke and heat alarms with replaceable 9V alkaline backup batteries. The alarms have a ten-year operational life and a five-year limited warranty. Compatible alarms can be hardwired together or wirelessly interconnected using the appropriate RadioLINK base or backplate.

Aico 3000 Series — Mains-Powered Premium / Grade D1

Mains-powered alarms with sealed rechargeable ten-year lithium backup cells and a ten-year guarantee. Options include optical smoke, heat, multi-sensor fire, carbon monoxide and combined heat/CO alarms. Compatible SmartLINK modules provide wireless interconnection, while AudioLINK+ supports data extraction on relevant products.

Aico 600 Series — Sealed-Battery / Grade F1

Battery-powered optical smoke, heat and multi-sensor alarms with sealed ten-year lithium batteries. Selected models include built-in AudioLINK+ and optional RadioLINK+ interconnection. These products can be supplied and fitted where a battery-powered Grade F1 solution is suitable.

Aico 200 Series — Carbon Monoxide Options

Sealed-battery carbon monoxide alarms are available in standalone and compatible RadioLINK+ versions. Product selection and positioning must suit the combustion risk, property and required interconnection.

Battery-powered alarms are not automatically suitable for every rental property, HMO, new installation or altered dwelling. The required grade and category must be established before the product is selected.

Compare Our Standard and Premium Aico Ranges

Feature

Ei140e Standard

3000 Series Premium

Power

230V mains

230V mains

Backup power

Replaceable 9V alkaline battery

Sealed rechargeable lithium cell

Alarm operational life

10 years

10 years

Product warranty/guarantee

5-year limited warranty

10-year guarantee

Alarm choices

Optical smoke and heat

Optical smoke, heat, multi-sensor and combined options

Interconnection

Hardwired or compatible RadioLINK base

Hardwired or compatible SmartLINK module

Alarm-status data

Standard test and alarm functions

AudioLINK+ on relevant products

Best suited to

Cost-effective standard installations

Enhanced features and reduced backup-battery maintenance

Electrician fitting a smoke detector in a residential property
Standard vs premium at a glance

Understanding Alarm Grades and LD Categories

  • System Grades

    The system grade describes how the alarms are powered and backed up.

    • Grade A — Separate detectors, sounders and central control and indicating equipment with standby power. This is outside the routine product-led service on this page and may be required in larger HMOs or communal buildings.

    • Grade C — Detectors and sounders connected to a common mains and standby supply with central control equipment. This is also outside AC1's routine domestic alarm offer.

    • Grade D1 — Mains-powered alarms with tamper-proof standby batteries. The Aico 3000 Series generally provides AC1's Grade D1 option.

    • Grade D2 — Mains-powered alarms with user-replaceable standby batteries. The Aico Ei140e Series generally provides AC1's Grade D2 option.

    • Grade F1 — Battery-powered alarms with sealed, tamper-proof batteries. Suitable Aico 600 Series products provide Grade F1 options where this grade is appropriate.

    • Grade F2 — Battery-powered alarms with user-replaceable batteries. These are not the principal products promoted by AC1.

  • LD Coverage Categories

    The LD category describes where alarms are installed and the extent of life-protection coverage.

    • LD1 — High protection: alarms throughout escape routes and in rooms or areas where a fire could start, excluding toilets, bathrooms and shower rooms.

    • LD2 — Medium protection: alarms cover escape routes together with specified higher-risk rooms or areas, normally including the kitchen and principal living space.

    • LD3 — Minimum protection: alarms cover circulation spaces forming escape routes, such as hallways and landings.

    The appropriate grade and category depend on the property type, occupancy, fire risk, regulations, licence conditions and any fire-risk assessment. A product or package must not be presented as suitable for every property without these factors being considered.

Interconnected Alarms Provide Warning Throughout the Property

When compatible alarms are interconnected, activation of one alarm causes the other linked alarms to sound, helping occupants hear the warning elsewhere in the property.

Hardwired Interconnection

A physical interlink cable connects compatible alarms. This may be suitable for new installations, rewires and properties where routes are accessible.

Wireless Interconnection

Compatible RadioLINK or SmartLINK equipment can interconnect alarms by radio signal. This can reduce the disruption, surface trunking and decoration associated with installing a new interlink cable.

Wireless interconnection does not necessarily make the alarms battery-only. Mains-powered alarms still require a suitable permanent electrical supply. The existing wiring, product compatibility, signal path and final arrangement must be checked before installation.

Electrician testing an interconnected smoke alarm system
How interconnected alarms work

Smoke, Heat and Carbon Monoxide Alarm Pricing

Provisional price basis to be confirmed by AC1 before publication. The following totals currently treat the standard Ei140e alarm as £25 + VAT, the 3000 Series premium alarm as £55 + VAT and compatible radio-interconnection equipment as £55 + VAT per alarm.

AC1 engineers on site in hi-vis reviewing inspection notes

Fixed Replacement Prices

Replacement option

Outside Congestion Charge Zone

Inside Congestion Charge Zone

First Ei140e standard replacement at an appointment

£120 + VAT (£144 inc VAT)

£135 + VAT (£162 inc VAT)

First 3000 Series premium replacement at an appointment

£150 + VAT (£180 inc VAT)

£165 + VAT (£198 inc VAT)

Each additional compatible Ei140e replacement during the same appointment

£72.50 + VAT (£87 inc VAT)

£80 + VAT (£96 inc VAT)

Each additional compatible 3000 Series replacement during the same appointment

£102.50 + VAT (£123 inc VAT)

£110 + VAT (£132 inc VAT)

AC1 office team member who acts as your dedicated point of contact

Standard New-Installation Prices

Installation option

Outside Congestion Charge Zone

Inside Congestion Charge Zone

Install one Ei140e standard alarm using a suitable local supply and standard cable route

£120 + VAT (£144 inc VAT)

£135 + VAT (£162 inc VAT)

Install one 3000 Series premium alarm using a suitable local supply and standard cable route

£150 + VAT (£180 inc VAT)

£165 + VAT (£198 inc VAT)

Each further standard Ei140e installation

£120 + VAT (£144 inc VAT)

£135 + VAT (£162 inc VAT)

Each further standard 3000 Series installation

£150 + VAT (£180 inc VAT)

£165 + VAT (£198 inc VAT)

Optional radio interconnection: add compatible RadioLINK or SmartLINK equipment for £55 + VAT (£66 inc VAT) per alarm.

HMO, communal, portfolio and non-standard systems: tailored quotation.

How the Prices Are Calculated

  • The first replacement includes the applicable one-hour minimum plus the selected alarm.

  • Each additional compatible replacement during the same appointment includes a half-hour labour allowance plus the selected alarm. The customer sees the complete fixed price rather than the internal time calculation.

  • Each standard new installation includes one hour of labour plus the selected alarm.

  • New-installation prices assume a suitable local permanent supply, normal access, standard mounting and a straightforward cable route.

  • Longer routes, extensive or decorative trunking, new circuits, specialist access, repairs, incompatible bases, making good, parking and other applicable costs are additional.

  • Selected battery-powered, combined, control and testing-only options require separately confirmed prices.

Electrician reviewing alarm installation pricing with a customer
How we work out your price

What Is Included and What Can Affect the Price?

  • What's Included in Standard Work

    Standard replacement assumptions:

    • Existing alarm and base are accessible

    • Existing wiring and supply are suitable

    • Replacement product is compatible with the existing system

    • No wiring repairs or alterations are required

    • Standard working hours and normal ceiling height

    • Functional testing of the replacement and compatible interconnected alarms

    New installation assumptions:

    • A suitable local supply or agreed circuit is available

    • Standard cable route and access

    • Standard mounting and commissioning

    • Agreed alarm type and interconnection method

    • Appropriate electrical certification where required

  • What Can Add to the Price

    • New circuits or extensive wiring

    • Incompatible or damaged bases and wiring

    • RadioLINK or SmartLINK modules

    • Control switches, interfaces, strobes or vibrating pads

    • Specialist access, high ceilings or asbestos-related restrictions

    • Parking, tolls and other applicable expenses

    • Making good, plastering or decoration

    • Further visits caused by inaccessible areas or incomplete information

Fire Detection for Homes

We install new alarm systems, replace alarms approaching their replacement date and upgrade older or incomplete arrangements in houses, flats, extensions and refurbished properties.

Homeowners may require work because alarms are expired, repeatedly chirping, damaged, incorrectly positioned, incompatible, no longer interconnected or insufficient for a changed property layout. We can inspect the existing arrangement, identify compatible replacement options and recommend smoke, heat and CO detection appropriate to the property.

Regular testing and timely replacement help maintain reliable protection. The date code and “replace by” marking should be checked, and an alarm should not be retained beyond the manufacturer's recommended life.

Row of residential houses and flats typical of properties AC1 Electrical Services works on
Reliable fire detection for every home

Alarms for Rental Properties, HMOs and Communal Areas

We can install, replace and test detection, verify compatible interconnection, record alarm details and provide commissioning, testing and completion records appropriate to the work.

AC1 engineers on site in hi-vis reviewing inspection notes

Smoke and Carbon Monoxide Alarms for Rental Properties

Landlords in England must provide at least one smoke alarm on each storey containing a room used wholly or partly as living accommodation. A carbon monoxide alarm is required in any room used as living accommodation containing a fixed combustion appliance, excluding gas cookers.

Landlords must ensure the required alarms are working at the start of a new tenancy and repair or replace them when a tenant reports a fault and the alarm is found not to be working. Keeping dated testing, installation and replacement records can help demonstrate that these duties have been managed.

These minimum legal duties do not automatically define the complete alarm design for every rental property. Building Regulations, BS 5839-6 recommendations, licensing conditions, property layout and fire risk may require a different grade, category or combination of alarms.

AC1 office team member who acts as your dedicated point of contact

Alarm Systems for HMOs and Communal Residential Areas

We can install and replace suitable mains-powered and battery-powered smoke, heat and carbon monoxide alarms in HMOs, shared houses, individual flats and appropriate communal residential areas.

The required system depends on the building layout, number of storeys, occupancy, escape strategy, HMO licence conditions, local-authority requirements, existing fire precautions and fire-risk assessment. Some buildings require different grades and categories within individual dwellings and communal areas.

This page covers domestic-type alarm systems designed and installed where appropriate under BS 5839-6. AC1 does not currently design or install conventional or addressable commercial fire-alarm panel systems. Buildings requiring Grade A or Grade C control equipment, manual call points, separate sounders, zoning, monitoring, commercial-system integration or a BS 5839-1 system must be referred for a separate specialist fire-alarm assessment.

Replacing Existing Smoke and Heat Alarms

A like-for-like alarm-head replacement may be straightforward where the existing base, wiring, supply, interconnection and compatible product remain suitable. The model number, manufacture date and replacement date should be checked before ordering.

A new base, wiring alteration or wider system upgrade may be required where:

  • The original alarm or range is discontinued

  • The replacement is not compatible with the existing base or interconnection

  • The wiring or base is damaged

  • Different manufacturers or incompatible ranges have been mixed

  • The alarm has been incorrectly positioned

  • The property requires additional or different detection

  • Repeated unwanted alarms indicate siting, contamination or sensor-selection issues

We will confirm the appropriate replacement approach from the information provided and, where necessary, assessment on site.

Electrician replacing a smoke alarm in a home
Like-for-like or a wider upgrade?

Book Smoke, Heat or Carbon Monoxide Alarm Work Online

  • Step 1

    Select the Work

    Choose replacement, new installation, system upgrade or request advice.

  • Step 2

    Tell Us About the Property

    Confirm property type, use, number of storeys, bedrooms, rooms requiring coverage and whether it is a rental property, HMO or communal area.

  • Step 3

    Provide the Existing Alarm Details

    Upload photographs and model numbers where available. Confirm whether alarms are mains powered and hardwired or wirelessly interconnected.

  • Step 4

    Choose Products or a Package

    Review available standard and premium alarm options, pricing, assumptions and optional wireless equipment.

  • Step 5

    Select a Preferred Appointment

    Choose an available routine appointment where the product and scope are suitable for direct booking.

  • Step 6

    Review and Confirm

    Accept the applicable price, terms and payment requirement. Complex, HMO, communal or non-standard systems may require office review before confirmation.

  • Step 7

    Installation and Handover

    The electrician installs or replaces the agreed alarms, tests the system and provides applicable records and user information.

Installation, Commissioning, Maintenance and Alarm Records

  • Installation, Commissioning and Maintenance

    Following a new installation or system alteration, we test the installed alarms, verify mains and standby power where applicable, test hardwired or radio interconnection and confirm the “one alarm, all alarm” function. We record the alarm types, models and locations, the applicable system grade and LD category where established, and any agreed limitations or variations.

    We can provide planned smoke, heat and carbon monoxide alarm inspections for individual properties, HMOs and property portfolios. This can include:

    • Functional testing of each alarm

    • Interconnection testing

    • Visual checks for damage, obstruction and contamination

    • Mains and standby-power checks

    • Fault and low-battery investigation

    • Manufacture, replacement-date and expiry checks

    • Compatibility and siting review

    • Testing of compatible control switches, strobes and vibrating pads

    • Identification of failed, damaged or expired alarms

    • Remedial recommendations and replacement works

    Domestic systems other than Grade A should generally be user-tested at least monthly in accordance with the manufacturer's instructions. Professional maintenance frequency should reflect the system grade, property type, fire risk, licence conditions and client requirements.

  • Commissioning and Record Sheets

    Depending on the work completed, AC1 can provide:

    • Installation and commissioning sheets

    • Routine inspection and testing sheets

    • Alarm schedules and asset registers

    • Make, model, location and replacement-date records

    • Interconnection and functional test results

    • Fault and remedial-work records

    • Photographic completion evidence

    • AudioLINK+ alarm-status reports for compatible products

    • Appropriate electrical certification

    • User testing, maintenance and handover information

    A straightforward compatible alarm-head replacement may receive a replacement and functional-test record rather than a complete new-system commissioning certificate. Documentation will reflect the actual scope completed.

Fire Alarm Installation and Replacement Across the South East of England

  • Hertfordshire

  • Essex

  • London

  • Cambridgeshire

  • Kent

  • Buckinghamshire

  • Surrey

  • Bedfordshire

  • Norfolk

  • Suffolk

Smoke, Heat and Carbon Monoxide Alarm FAQs

Need New, Replacement or Tested Alarm Protection?

Choose an alarm replacement, compare mains-powered and battery-powered options, book an inspection and testing visit, or tell us about the property so we can recommend the appropriate smoke, heat and carbon monoxide detection.

Speak to our expert team today